PART II - INSPECTIONS



The inspections, which are listed below, are performed while acting for the jurisdiction in good faith and without malice in the discharge of the duties required by this code or other pertinent law or ordinances, shall not thereby be rendered liable personally and is hereby relieved from personal liability for any damage accruing to persons or property as a result of any act or by reason of any act or omission in the discharge of official duties. (R104.8) The quality and structural strength of the project is the responsibility of the builder and cannot be achieved with only a few inspections during construction. A copy of the plans must be on site. To schedule an inspection, call 866-2054.

It shall be the duty of the person doing the work or the permit holder to notify the building official 24 hours in advance that such work is ready for inspection. (R109.3) A 4-hour notice is required for concrete and sewer inspections. It shall also be the duty of that person to provide access to and means for inspection of such work. (R109.3) Silt Fence or other approved erosion controls are required at all down-slope locations to prevent soil leaving the property.

1. Footing Inspection – A footing inspection is required after all steel is in place and prior to placing of concrete. (R109.1.1)


2. Wall Inspection – All foundation walls will be inspected after all steel is in place and prior to placing of concrete. (R109.1.5)


3. Sewer Inspections - A sewer inspection is required after the building sewer is connected to the sewer “Y” and before backfilling. (R 109.1.5)


4. Ground Rough Plumbing Inspection– All underground or under slab plumbing must be inspected prior to covering. (R109.1.5)


5. Erosion Control Inspection – Silt Fence or other approved erosion control must be installed on all down-slopes and along curb line. The gravel base for the driveway must be installed to allow access to the property during construction, with silt fencing located in all other areas along roadways. All erosion controls must be maintained throughout construction and further inspections can be rejected if not maintained.


6. Rough-In Inspection- All rough plumbing must be inspected when drain/waste/vents and water piping are roughed in prior to insulating. (R109.1.2) Framing-Building framing must be inspected after all framing and furring is completed, prior to insulating or drywall stocking. (R109.1.2) Electrical-The electrical wiring must be inspected after all wiring, boxes, and recessed fixtures are installed. Boxes should be made up and home runs should extend to the service location. The inspection must be approved prior to insulating or drywall stocking. The service must be inspected before KCP&L will provide electricity. The service panels disconnect, and service entrance conductors need to be complete for service panels and sub panels. The panel cover should be off but available nearby. Mechanical-Mechanical vents, ducts, and return air spaces require inspection prior to insulation or drywall stocking. (R109.1.2) Electric and gas service will not be released to the utility company until all rough-in inspections have been approved. (R111.1)


7. Driveway/Sidewalk

Inspections - Inspections are needed for driveway approaches and public sidewalks prior to placing concrete. See Approach in Appendix A. (R109.1.5)


8. Occupancy Inspection - An occupancy inspection is required prior to any occupancy of a building or addition. All electrical connections, faceplates, panels, and fixtures must be complete. Plumbing fixtures, mechanical equipment, final grade, sidewalks, driveways and safety features such as handrails, guardrails, and smoke detectors must be completed. (R109.1.6). All landscaping and site work shall be completed, weather dependant, prior to a final inspection. In the event this is not completed a Temporary Occupancy may be issued by the Building Inspector.


9. Inspection Agencies – For weekend or holiday inspections, the building inspector is authorized to accept reports of approved agencies, provided such agencies satisfy the requirements as to qualifications and reliability. The contractor must request approval of the agency prior to the inspection to allow the building inspector to investigate its qualifications.

1   2   3   4   5   6

Похожие:

Part III building Guidelines iconPart III: The Political Use of the Myth

Part III building Guidelines iconM. Sc. (Physics) part-ii (III & IV semester)

Part III building Guidelines iconWeb ct guidelines for using Webct 27-30 Staff Contact Details Academic and Support Staff Contact Details 31-32 part one general information

Part III building Guidelines iconPrincipal Department for Transport, Energy and Infrastructure, Building Management Building the Education Revolution hotline: 82077144 introduction

Part III building Guidelines iconRemember: The Air France Concorde crashed into a hotel building after takeoff from Charles de Gaulle airport on 25 July 2000. Points to be noted here that building didn't collapse as in 911 in New York

Part III building Guidelines iconСписок литературы. Логика Арно А. Николь П. «Логика как искусство мыслить» П. Б. Струве «Логика для женской гимназии» Асмус В. Ф. «Логика» Москва 1947г. «Формальная логика» лгу 1977г
«Journal of symbolic logic» 1934г., VI part 4, XXVI part 1-2? 1960 г., V part 4-5, 1980г

Part III building Guidelines icon2003 international building code modified for the 2004 florida building code

Part III building Guidelines icon2003 international building code modified for the 2004 florida building code

Part III building Guidelines iconСтроительные нормы и правила сниП 03. 01-87 "Несущие и ограждающие конструкции" (утв постановлением Госстроя СССР от 4 декабря 1987 г. N 280) (с изменениями от 22 мая 2003 г.)
Взамен снип iii-15-76; сн 383-67; снип iii-16-80; сн 420-71; снип iii-18-75; снип iii-17-78; снип iii-19-76; сн 393-78

Part III building Guidelines iconRoe V. Wade (No. 70-18) 314 F. Supp. 1217, affirmed in part and reversed in part


Разместите кнопку на своём сайте:
lib.convdocs.org


База данных защищена авторским правом ©lib.convdocs.org 2012
обратиться к администрации
lib.convdocs.org
Главная страница